ICA SOLAR SNV-GH3041 3kW/48V

ICA SOLAR SNV-GH3041 is a hybrid bidirectional single phase solar inverter with capacity of 3000W, 48Vdc.

Brands :

ICA SOLAR

Categories :

Hybrid
Informasi Umum
Bi-directional Power Flow
Charges batteries from solar or grid, and discharges to supply loads or feed back to the grid.
Seamless Backup
Automatically switches to battery during grid outages for uninterrupted power.
High Efficiency
Optimized conversion reduces energy loss and improves savings.
Remote Monitoring
Access system performance data anytime, anywhere.
Pure sine wave output
Self-consumption and feed-in to the grid
Programmable supply priority for PV, battery or grid
User-adjustable charging current and voltage
Operation modes: Grid-tied, off-grid and grid-tied with backup
Monitoring software for real-time status display and control
Parallel operation up to 9 units
Battery independent system
Spesifikasi Teknis
Rated Output Power (W)
3.000 W
Battery Nominal DC Voltage
48 Vdc
Max. PV Input DC Voltage
450 Vdc
MPPT Voltage Range
120–430 Vdc
Max. Charging Current
60 A
Phase
1-phase in/1-phase out
Dimensions (D x W x H)
120 x 295 x 468 mm
Net Weight
11 kg
Max. PV Input Power
4.000 W
PV Input (DC)
Nominal DC Voltage / Max. DC Voltage
360 Vdc/450 Vdc
Number of MPPTs / Max. Input Current
1/18 A
Grid-Tied Grid Output (AC)
Nominal Output Voltage
220/230/240 Vac
Output Voltage Range
184–264,5 Vac or 195,5–253 Vac (selectable)
Output Frequency Range
47,5–51,5 Hz or 49–51 Hz (selectable)
Nominal Output Current
13 A
Power Factor (cos Φ)
>0,99
Efficiency
Max. Conversion Efficiency (DC/AC)
95%
Off-Grid & Hybrid Operation
AC Input
Acceptable Input Voltage Range
90–280 Vac or 170–280 Vac
Frequency Range
50 Hz/60 Hz (auto sensing)
Battery Mode Output (AC)
Nominal Output Voltage
220/230/240 Vac
Output Waveform
Pure Sine Wave
Nominal Output Frequency
50 Hz
Efficiency (DC to AC)
93%
Battery & Charger
Max. Solar Charging Current
60 A
Max. AC Charging Current
60 A
Interface
Parallel Function
Yes, up to 9 units
Communication Interface
USB or RS-232/Dry contact
Environment
Relative Humidity
0–90% (non-condensing)
Operating Temperature Range
-10°C to 50°C
Datasheet
Brochure
Supporting Articles & Videos
No data was found
Proyek Terkait
No data was found

Minta Penawaran

Tulis jumlah dan lokasi kirim. Tim sales ICA mengirim penawaran lewat WhatsApp atau email.